Precor C960 Series
Error Codes
How to enter diagnostics mode:
To access lift and test limit switches, press SPEED UP, SPEED DOWN and
INCLINE UP simultaneously and scroll through diagnostics.
MESSAGE |
REASON FOR
ERROR
|
RECOMMENDED
ACTION
|
PACE
ERROR 1 |
Motor
accelerating too fast. |
Check
SCR, lower board, ribbon cable, upper board.
|
PACE
ERROR 2 |
Drive
pulse rate and feedback pulse rate do not agree.
|
Check
hall effect sensor, motor brushes, SCR, lower board.
|
PACE
ERROR 3 |
Motor
control pulses sent no response from feedback circuit.
|
Check
motor, motor brushes, lower board, ribbon cable, wiring, upper board.
|
PACE
ERROR 4 |
Motor
drive pulses interrupted while treadmill is operating.
|
Check hall effect
sensor, lower board, ribbon cable, upper board.
|
PACE
ERROR 5 |
No
response when directed to stop under manual or software control. |
Check
keypad, upper board. |
PACE
ERROR 6 |
Loss
of 60 Hz internal reference voltage. |
Check
lower board, ribbon cable, upper board. |
PACE
ERROR 7 |
Feedback
pulse width not correct. |
Check
hall effect sensor, motor brushes, running bed, running belt, rollers,
drive belt, etc. |
LIFT
ERROR |
Lift
inoperative. |
Check
lift fuse, lift capacitor, lift motor, lower board, ribbon cable,
upper board. |
LIFT
ERROR |
Unable
to complete calibration. |
Check
0-degree micro switch revolution counter, ribbon cable, upper board.
|
PROGRAM
ERROR |
Checksum
read error. |
Check
prom, upper board. |
LINE
FREQUENCY ERROR |
Noisy
or incorrect line frequency or voltage. |
Check
for correct line voltage frequency, dedicated circuit. |
STACK
ERROR |
Software
Error. |
Check
prom, upper board. |
MEMORY
ERROR |
Software
Error. |
Check
prom, upper board. |
KEY
PRESSED |
Key
pressed during power up. |
Check
keypad, upper board. |
|